AbstractHydrodynamics and effective interfacial area in a 25 mm i.d. packed tube column were studied over a wide range of operating conditions for demister pad packings (DPP). Flow maps have been prepared. Values of effective interfacial area as high as 1880 m−1 in the spray flow regime were obtained. Data on pressure drop and effective interfacial area have been correlated for different flow regimes. Values of liquid side volumetric mass transfer coefficient, kL a, were measured by absorption and desorption of oxygen in different packed tube columns containing Pall rings (standard and low height to dia. ratio), multifilament wire gauge packings (MFWGP) and DPP. kL a was found to vary from 0.017 to 0.34 s−1 for DPP.Values of wall side solid‐liquid mass transfer coefficient, kSL, were obtained in a 25 mm i.d. copper tube column packed with MFWGP by the dissolution of copper in acidic dichromate solutions. Values of wall side heat transfer coefficient could be obtained by analogy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.