Abstract

As an efficiency heat and mass transfer method, thin liquid film has been widely used in industry. This paper studies on liquid nitrogen laminar film flows in the brazed cryogenic heat exchanger with 2.3mm distance between plates. Simplified theoretical models are established based on the characteristics of both the dynamic and heat and mass transfer of nitrogen film. Relationship between the dimensionless thickness and the coefficient of heat convection of liquid nitrogen film is derived. And the impact of rate of vapor content, intensity of interfacial convection heat transfer and Reynolds numbers are calculated and analyzed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.