Abstract

A one-dimensional hydrodynamic model of a dielectric-barrier discharge (DBD) in pure chlorine is developed, and the properties of the discharge are modeled. The discharge is excited in an 8-mm-long discharge gap between 2-mm-thick dielectric quartz layers covering metal electrodes. The DBD spatiotemporal characteristics at gas pressures of 15–100 Torr are modeled for the case in which a 100-kHz harmonic voltage with an amplitude of 8 kV is applied to the electrodes. The average power density deposited in the discharge over one voltage period is 2.5–5.8 W/cm3. It is shown that ions and electrons absorb about 95 and 5% of the discharge power, respectively. In this case, from 67 to 97% of the power absorbed by electrons is spent on the dissociation and ionization of Cl2 molecules. Two phases can be distinguished in the discharge dynamics: the active (multispike) phase, which follows the breakdown of the discharge gap, and the passive phase. The active phase is characterized by the presence of multiple current spikes, a relatively high current, small surface charge density on the dielectrics, and large voltage drop across the discharge gap. The passive phase (with no current spikes) is characterized by a low current, large surface charge density on the dielectrics, and small voltage drop across the discharge gap. The peak current density in the spikes at all pressures is about 4 mA/cm2. In the multispike phase, there are distinct space charge sheaths with thicknesses of 1.5–1.8 mm and a mean electron energy of 4.3–7 eV and the central region of quasineutral plasma with a weak electric field and a mean electron energy of 0.8–3 eV. The degree of ionization of chlorine molecules in the discharge is ~0.02% at a pressure of 15 Torr and ~0.01% at 100 Torr. The DBD plasma is electronegative due to the fast attachment of electrons to chlorine atoms: e + Cl2 → Cl + Cl–. The most abundant charged particles are Cl 2 + and Cl− ions, and the degree of ionization during current spikes in the active phase is (4.1–5.5) × 10–7. The mechanism of discharge sustainment is analyzed. The appearance of a series of current spikes in the active phase of the discharge is explained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.