Abstract

In this paper, the application of the hydrodynamic analysis in the selected ‘pumping and treatment’ remediation method of groundwater hydrocarbon pollution in the case of the Pancevo oil refinery is examined. The applied hydrodynamic analysis represents a regular and necessary approach in modern hydrogeology. Previous chemical analysis of soil and groundwater samples at observation objects revealed their pollution by oil products. New researches included the constraction of 12 piezometric boreholes of varying depths, geoelectric soil sounding, ‘in situ’ measurement of the present contaminant, detected as a hydrophobic phase of LNAPL, chemical analysis of soil and groundwater samples with emphasis on total petroleum hydrocarbons (TPH) content, total fats and mineral oils, mercury cations and other characteristic compounds, etc. These researches define the volume of contamination issued by the ‘light’ (LNAPL) contamination phase. The selected remediation method for this type of pollution is the ‘Pump and Treat’ method, which implies the pumping of contaminated groundwater from aquifer and their subsequent treatment. A hydrodynamic method was used to select the optimal hydrotechnical solution for LNAPL extraction. On the mathematical model, the prediction calculations for two variant solutions were carried out (‘hydraulic isolation’ and complex) for the application of groundwater contamination remediation characterized as front pollution substance (by extraction and injection wells or infiltration pool). By extraction wells performing, it would be possible to remove the LNAPL from the surface of the water with special pumps-skimmers. The importance of the hydrodynamic method application is, in addition to the hydrotechnical solution selection for the LNAPL drainage, the provision of quality basis for the dimensioning of these objects based on the results of the groundwater balance.

Highlights

  • Previous chemical analysis of soil and groundwater samples at observation objects revealed their pollution by oil products

  • New researches included the constraction of 12 piezometric boreholes of varying depths

  • These researches define the volume of contamination issued by the "light

Read more

Summary

PB-2 nije uzet uzorak nije uzet uzorak

Sadržaj ukupnih ulja i masti u podzemnim vodama na ovim pijezometrima iznosi i do 60 g/l, a na nekim se nije ni mogla izmeriti navedenim metodama. Pri različitim nivoima reke Dunav, a samim tim i režimima podzemnih voda, izmerene su debljine ove faze zagađenja u intervalu 0,6- 1,6 m (izuzetno male elektroprovodljivosti

REZULTATI I DISKUSIJE
ZAKLJUČAK
SUMMARY
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.