Abstract

Abstract A major component of the Southern Oxidants Study (SOS) 1992 Atlanta Intensive was the measurement of atmospheric nonmethane hydrocarbons. Ambient air samples were collected and analyzed by a network of strategically located automated gas chromatography (GC) systems (field systems). In addition, an extensive canister sampling network was deployed. Combined, more than 3000 chromatograms were recorded. The SOS science team targeted for quantitative analysis 56 compounds which may be substantial contributors to ozone formation or used as air mass tracers. A quality assurance program was instituted to ensure that good measurements were being made throughout the network for each target compound. Common, high-quality standards were used throughout the network. The performance of individual field systems was evaluated during the intensive through the analysis of challenge mixtures. This methodology helped to identify and correct analytical problems as they arose.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.