Abstract
Experimental measurements by wavepacket reflectometry are carried out to verify the low transmission loss of hybrid mode on HE11 in the corrugated waveguide with 88.9 mm in diameter. The HE11 mode is injected into the 62-m straight circular corrugated waveguide and the beat between the HE11 and HE21 (including degenerated TE01 and TM02) modes is observed. The loss is too small to measure and inferred to be less than 2 db/km. The result shows that the use of HE11 mode for electron cyclotron heating system is suitable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Infrared and Millimeter Waves
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.