Abstract
In the case of linear time-invariant networks, a set of simple recursive formulae are deduced for the first- and higher order sensitivity coefficients of the network voltages and currents with respect to the component values. These formulae are based on Branin's hybrid formulation method but include terms corresponding to dependent drivers. It is shown that the chief computational effort in using these formulae involves a single matrix inversion or LU factorization carried out once.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.