Abstract

The hybrid branchline coupler consists of two transmission lines connected alternately by /spl lambda//4 shunt and series branches. The analysis of this structure leads to a class of directional couplers of which the parallel transmission-line and the de Ronde strip-slot types may be regarded as special cases. From the precise design data thus available, a number of 3-dB strip-slot couplers have been built in C band and X band with a performance close to the predicted one.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.