Abstract

Expanding dc electrical distribution systems require improved detection and mitigation of dc arc events. The high heat resulting from dc arcing raises concerns on equipment and personnel safety. In this article, a new adaptive detection method for series dc arc faults is presented. The proposed detection method utilizes Hurst exponent estimation of the system current to detect arcing events with a high detection rate and strong immunity against sudden load changes, chaotic load profiles, and switching harmonics. To verify the proposed detection method, a test setup to generate dc arcs was built, and over one thousand tests were performed under various conditions. The tests were conducted under different environment temperatures, air gap lengths, loads, and electrode diameters. The effectiveness of the proposed method is demonstrated by the test results and validated with an arc detector prototype.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.