Abstract

BackgroundsAn outbreak of lung injury among South Korean adults was examined in a hospital-based case-control study, and the suspected cause was exposure to humidifier disinfectant (HD). However, a case-control study with community-dwelling controls was needed to validate the previous study’s findings, and to confirm the exposure-response relationship between HD and lung injury.MethodsEach case of lung injury was matched with four community-dwelling controls, according to age (±3 years), sex, residence, and history of childbirth since 2006 (for women). Environmental risk factors, which included type and use of humidifier and HD, were investigated using a structured questionnaire during August 2011. The exposure to HD was calculated for both cases and controls, and the corresponding risks of lung injury were compared.ResultsAmong 28 eligible cases, 16 patients agreed to participate, and 60 matched controls were considered eligible for this study. The cases were more likely to have been exposed to HD (odds ratio: 116.1, 95% confidence interval: 6.5–2,063.7). All cases were exposed to HDs containing polyhexamethyleneguanidine phosphate, and the risk of lung injury increased with the cumulative exposure, duration of exposure, and exposure per day.ConclusionsThis study revealed a statistically significant exposure-response relationship between HD and lung injury. Therefore, continuous monitoring and stricter evaluation of environmental chemicals’ safety should be conducted.

Highlights

  • In April 2011, a tertiary university hospital in Seoul reported an outbreak of adult patients with unexplained severe respiratory distress to the Korea Centers for Disease Control and Prevention (KCDC)

  • The cases were more likely to have been exposed to humidifier disinfectant (HD)

  • The patients all progressed to severe pneumonia without fever, which was analogous to acute interstitial pneumonia or idiopathic acute respiratory distress syndrome

Read more

Summary

Methods

Each case of lung injury was matched with four community-dwelling controls, according to age (±3 years), sex, residence, and history of childbirth since 2006 (for women). Environmental risk factors, which included type and use of humidifier and HD, were investigated using a structured questionnaire during August 2011. The exposure to HD was calculated for both cases and controls, and the corresponding risks of lung injury were compared

Results
Introduction
Materials and Methods
Discussion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call