Abstract

The sample was extracted under the ultrasonic assistance and purified through the solid-phase extraction, and then the residual tylosin in soil was detected via the high-performance liquid chromatography (HPLC). Acetonitrile-aqueous solution was used as the extracting agent in the ultrasound-assisted extraction. The HLB solid-phase extraction column was activated using 5 mL of methanol and 5 mL of ultrapure water, leached with 5 mL of water and 5 mL of 2% ammonium hydroxide + 5% methanol solution, and eluted with 5 mL of methanol in the end. The determination was implemented using the HPLC method, where the detected wavelength λ value was 290 nm, the sample size was 20μL, and the column temperature was 30°C. Acetonitrile -0.01 mol/L monopotassium phosphate solution (pH=2.5) = 60:40 (V: V) was taken as the mobile phase in the detection of response degree to tylosin in soil. The detection results were as follows: LOD was 0.019mg/kg, LOQ was 0.062mg/kg, the coefficient of variation of intra-day precision was smaller than 10%, and that of inter-day precision was smaller than 15%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.