Abstract
P-glycoprotein (Pgp) is a 170-kDa membrane transporter that mediates drug efflux and is an effector of multidrug resistance. SDZ PSC 833 (PSC), a nonimmunosuppressive cyclosporine that potently modulates Pgp, is currently under clinical evaluation in patients with cancer. We have developed a reversed-phase HPLC assay for determining PSC blood concentrations that utilizes a step gradient with linear segments to resolve PSC into two distinct peaks (likely to be keto and enol isomers). To clinically validate the assay, PSC concentrations were obtained by HPLC from nine patients receiving oral doses of 5 mg/kg every 6 h. Values ranged from 0.91 to 5.4 mg/L during the dosing period, comparable with concentrations of PSC that modulate Pgp in vitro. In addition, we investigated the immunoreactivity of the Abbott TDx cyclosporin A (CsA) monoclonal whole-blood assay for PSC. The TDx CsA assay cross-reacts approximately 17% with PSC as determined by adding known amounts of PSC to whole blood. When PSC concentrations obtained by the TDx CsA assay were divided by 0.17, we found agreement between the TDx CsA assay and the HPLC PSC assay for samples from nine patients.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.