Abstract
A method is proposed for the extraction, separation, identification and quantitative measurement of rhodamine B in cosmetics samples The colour is extracted with a solution of orthophosphoric acid in either water or DMF (depending on the type of cosmetic) adsorbed on a polyamide column, and then eluted with water and methanol. Further clean-up of the extract is performed by means of a Bond Elut C-18 cartridge, from which rhodamine B is eluted with methanol-water (8∶2). The final eluate is examined by HPLC. Chromatography is performed on a C-18 column with a gradient elution from 50∶50 to 70∶30 of acetonitrile-water, containing 0.1 M sodium perchlorate, in 15 min. A diodearray detector enables peak purity analysis. The method gives recovery values of approximately 90%, or better, and the reproducibility is within 4%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.