Abstract

We describe an HPLC-based method for the detection and quantification of fetal hemoglobin in stools of newborns. The new procedure is an alternative to the classic qualitative test for adult hemoglobin in meconium based on the differential stability of hemoglobin species in dilute base (Apt test). The HPLC method, based on a commercial device for hemoglobin characterization (Bio-Rad Variant), readily separates fetal and adult hemoglobin from non-hemoglobin components of meconium. To validate the method, blood and meconium were mixed in various proportions and then prepared for analysis with extraction in saline. The HPLC method accurately identified hemoglobin species even when the blood constituted only 5 mL per 100 g of the meconium specimen, and nearly quantitative recovery of hemoglobin was obtained at a blood content of 20 mL per 100 g of the meconium. Analysis time was 6.5 min, and preparation of sample was simple. HPLC detection of fetal blood in stools or other specimens markedly improves detection/characterization of blood in meconium.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.