Abstract

Ingested foreign bodies are a common presentation to paediatric ENT services. Depending on the site, these are usually managed with flexible or rigid oesophagoscopy and retrieval. This paper presents a novel technique for removing a hollow foreign body that could not be removed using conventional means. After rigid and flexible approaches failed, a guidewire was passed through the foreign body under fluoroscopic guidance and a dilatation balloon passed through the lumen of the object. Inflating the balloon allowed dilatation of the inflamed mucosa above and below the object, facilitating straightforward removal under traction. This is a novel and reproducible technique that uses equipment readily available in tertiary referral centres. Employed in this context, the technique enabled removal of an impacted object surrounded by granulation tissue, and would be appropriate for other objects with a lumen.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.