Abstract
Abstract— In conventional LCDs, the backlight is set to maximum luminance regardless of the image. For dark scenes, this approach causes light leakage and power waste. Especially, light leakage in dark scenes degrades the contrast ratio of LCDs; to circumvent this problem, local‐dimming systems have been proposed. In these systems, the LED backlight is divided into several local blocks and the backlight luminance of each local block is controlled individually, and pixel values are adjusted simultaneously according to the luminance profile of the dimmed backlight. In this paper, a method of determining the LED backlight luminance of each local block depending on the image is proposed; this method significantly improves the image quality of LCDs. First, we introduce methods of quantifying light‐leakage at dark gray levels and clipping at bright gray levels. Then, the proposed method to determine the dimming duty, which controls the LED backlight luminance by compromising between these two measures, was derived. The proposed algorithm preserves the original image with little clipping distortion and effectively reduces light leakage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.