Abstract

IntroductionIn out-of-hospital cardiac arrests (OHCAs), the use of an automatic external defibrillator (AED) by a bystander remains low, as AEDs may be misplaced with respect to the locations of OHCAs. As the distribution of historical OHCAs is potentially predictive of future OHCA locations, the purpose of this study is to assess AED positioning with regard to past locations of OHCAs, in order to improve the efficiency of public access defibrillation programs.MethodsThis is a retrospective observational study from 2014 to 2018. The locations of historical OHCAs and AEDs were loaded into a geodata processing tool. Median distances between AEDs were collected, as well as the number and rates of OHCAs covered (distance of <100 meters from the nearest AED). Areas with high densities of uncovered OHCAs (hotspots) were identified in order to propose the placement of additional AEDs. Areas over-covered by AEDs (overlays) were also identified in order to propose the relocation of overlapping AEDs.ResultsThere were 2,971 OHCA, 79.3% of which occurred at home, and 633 AEDs included in the study. The global coverage rate was 7.5%. OHCAs occurring at home had a coverage rate of 4.5%. Forty hotspots were identified, requiring the same number of additional AEDs. The addition of these would increase the coverage from 7.5% to 17.6%. Regarding AED overlays, 17 AEDs were found to be relocatable without reducing the AED coverage of historical OHCAs.DiscussionThis study confirms that geodata tools can assess AED locations and increase the efficiency of their placement. Historical hotspots and AED overlays should be considered, with the aim of efficiently relocating or adding AEDs. At-home OHCAs should become a priority target for future public access defibrillation programs as they represent the majority of OHCAs but have the lowest AED coverage rates.

Highlights

  • In out-of-hospital cardiac arrests (OHCAs), the use of an automatic external defibrillator (AED) by a bystander remains low, as AEDs may be misplaced with respect to the locations of OHCAs

  • As the distribution of historical OHCAs is potentially predictive of future OHCA locations, the purpose of this study is to assess AED positioning with regard to past locations of OHCAs, in order to improve the efficiency of public access defibrillation programs

  • There were 2,971 OHCA, 79.3% of which occurred at home, and 633 AEDs included in the study

Read more

Summary

Introduction

In out-of-hospital cardiac arrests (OHCAs), the use of an automatic external defibrillator (AED) by a bystander remains low, as AEDs may be misplaced with respect to the locations of OHCAs. As the distribution of historical OHCAs is potentially predictive of future OHCA locations, the purpose of this study is to assess AED positioning with regard to past locations of OHCAs, in order to improve the efficiency of public access defibrillation programs

Methods
Results
Discussion
Materials and methods
Ethical approval
Limitations
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.