Abstract

In appropriately selected patients with COVID-19 acute respiratory distress syndrome, venovenous extracorporeal membrane oxygenation (VV ECMO) may offer a promising bridge to lung recovery or lung transplantation if lung recovery fails. Although the cannulation technique for VV ECMO via a right internal jugular (RIJ) dual-lumen catheter (DLC) requires expertise and guidance by either fluoroscopy or transesophageal echocardiography (TEE), it offers theoretical circulatory support advantages by using bicaval venous drainage to deliver oxygenated blood systemically with minimal recirculation as compared with the femoral vein and RIJ dual-site cannula configuration. In addition, patients are often too unstable to transport safely to an operating room or catheterization laboratory, and fluoroscopy is not always readily available to guide RIJ DLC placement. Here, we provide a comprehensive description of a safe, bedside protocol for VV ECMO cannulation via a RIJ DLC under TEE guidance. We will report our center's experience (March 30, 2020 to November 21, 2021) and discuss important hemodynamic, safety, and infection control considerations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.