Abstract
Generation of an infinite series of identical sub-trees may occur during the construction of a Fault Tree (FT) when one item of equipment in a plant is considered several times in the same sub-tree in the course of the tree extraction from a HazOp (Hazard Operability analysis) analysis. Generation of loops in the construction of an FT can be avoided by means of an ad hoc logical analysis in which certain simple rules of syntax are taken into account. A radical solution, however, can be obtained if identification of unwanted events in a process plant is not undertaken with conventional procedures, such as HazOp (Operability Analysis with guide words, failure mode and effect analysis (FMEA) etc.), but with a more modern and structured version, such as Recursive Operability Analysis (ROA), which is both systematic and complete, and allows direct extraction of logic trees, (FT, event trees, etc.) for subsequent quantification. This feature means that, by contrast with conventional operability analysis, the congruence of the ROA itself can be checked. The ROA method is illustrated in this paper with the aid of some simple examples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.