Abstract

This investigation evaluated the risk of overexposure for a selected assigned protection factor by performing Monte Carlo simulations. A model was constructed to assess respirator performance by calculating the concentration inside the respirator. Estimates of the factors that affect respirator performance were described as distributions. The distributions used a worst case estimate for concentration in the workplace, the worst case for respirator performance (the fifth percentile person), and the worst case for exhalation valve leakage. A Monte Carlo analysis then provided estimates of the percentage of time that concentration inside the respirator exceeded the occupational exposure limit (OEL). For a half-facepiece respirator with an APF of 10, the calculations indicated a low risk of being exposed above an OEL, with mean exposures being controlled well below an OEL.