Abstract

The purpose of our survey is to analyse the clinical approach used to prevent and treat cardiovascular implantable electronic device (CIED) infections in Europe. The survey involves high-volume implanting centres. According to the survey the incidence of CIED infections shows a slight decrease in most centres and is substantially under 2% in the majority of centres interviewed. However, there are still differences in terms of prophylactic antibiotic therapy: 8.9% of the centres administer oxacillin as preoperative treatment, 4.4% of them do not give any antibiotic therapy, all centres use some kind of skin antisepsis, but only 42.2% use chlorhexidine. In case of local infection, 43.5% of centres perform lead extraction as first approach. In the case of systemic infection or evidence of lead or valvular endocarditis, 95% of centres treat these conditions by extracting the leads, which indicates that the adherence to the lead extraction guidelines is quite good.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.