Abstract

We investigated the quantitative effect and risk factors for over-release during multiple needle puncturing (MNP) for medial gap balancing in varus total knee arthroplasty (TKA). Of the ten pairs of cadaveric knees, one knee from each pair was randomly assigned to undergo MNP in extension (E group), while the other knee underwent MNP in flexion (F group). The increased extension and 90° flexion gaps after every five needle punctures were measured until over-release occurred. The extension gap (< 4mm) and the 90° flexion gap (< 6mm) gradually increased in both groups. The 90° flexion gaps increased more selectively than did the extension gaps. MNP in the flexed knee, a narrow MCL, and severe osteoarthritis were associated with a smaller number of MNPs required to over-release.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.