Abstract

The photocatalytic degradation of toluene in indoor air conditions was performed in a closed-loop multi-pass photocatalytic reactor using the Box-Behnken experimental design methodology. The objective of this work was to rigorously determine a kinetic model in order to understand the behavior of the reactor in real indoor air conditions and to relate the kinetic parameters to physical and chemical mechanisms. Three main parameters were studied: initial toluene concentration, light irradiance and air stream velocity. The experimental results were used to calculate the single-pass removal efficiency for different operating conditions and to establish a relationship between the single-pass removal efficiency, light irradiance and air stream velocity. This relationship was integrated into an overall reaction rate law based on the Langmuir-Hinshelwood mechanism. The kinetic model obtained was then validated for various experimental conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.