During 13 winter weeks, an experimental archeology project was undertaken in two Danish reconstructed Viking Age houses with indoor open fireplaces. Volunteers inhabited the houses under living conditions similar to those of the Viking Age, including cooking and heating by wood fire. Carbon monoxide (CO) and particulate matter (PM2.5 ) were measured at varying distances to the fireplace. Near the fireplaces CO (mean) was 16ppm. PM2.5 (mean) was 3.40mg/m(3) , however, measured in one house only. The CO:PM mass ratio was found to increase from 6.4 to 22 when increasing the distance to the fire. Two persons carried CO sensors. Average personal exposure was 6.9ppm, and from this, a personal PM2.5 exposure of 0.41mg/m(3) was estimated. The levels found here were higher than reported from modern studies conducted in dwellings using biomass for cooking and heating. While this may be due to the Viking house design, the volunteer's lack of training in attending a fire maybe also played a role. Even so, when comparing to today's issues arising from the use of open fires, it must be assumed that also during the Viking Age, the exposure to woodsmoke was a contributing factor to health problems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.