Abstract
ObjectiveFluorescence contrast technology using indocyanine green (ICG) could be useful for the rapid, dynamic, and objective assessment of blood vessels and the surrounding tissues when combined with near-infrared (NIR) imaging. Although ICG is a clinically available NIR fluorescence imaging probe, it can easily aggregate and is, thus, unstable. In the present study, we examined the efficacy of a host–guest ICG–β-cyclodextrin (CD) complex, which is used in pharmaceutics to improve the water solubility, stability, and bioavailability of hydrophobic molecules, for NIR imaging after hind footpad administration in a rat model. MethodsTo verify the performance of the ICG-β-CD complex with the host–guest self-assembly method in vivo, we performed simultaneous small animal (IVIS Spectrum system; PerkinElmer, Waltham, MA) and clinical (DIGI-MIH-001 near-infrared fluorescence imaging system; Beijing Digital Precision Medical Technology Co, Ltd, Beijing, China) imaging and evaluated the fluorescent properties of the ICG-β-CD complex in the hind footpad model of Sprague-Dawley male rats. ResultsWe successfully prepared the ICG-β-CD complex. Compared with ICG, in vivo experiments showed that this complex had reduced absorbance at 710 nm and increased absorbance at 780 nm, indicating that it could prevent the dimeric aggregation of ICG, and a significantly higher fluorescence intensity at 730 nm excitation. After injection of 1.25 mg/mL of ICG or ICG-β-CD complex solutions into the rat hind footpad, fluorescent NIR lymphatic images were observed with both imaging systems. During the 12-hour observation period, the signal background ratio of ICG-β-CD showed a greater acute increase and a higher signal background ratio compared with ICG. The signal background ratio of ICG-β-CD was 125 to 100 from 260 to 540 minutes. These in vivo data suggest that ICG-β-CD has greater diffusion from the injection site and faster transport to the lymphatic system compared with ICG. ConclusionsICG-β-CD showed faster lymphatic transport than ICG, allowing for more rapid lymphatic NIR imaging. Thus, the ICG-β-CD complex might be a promising fluorescent agent for clinical lymphatic NIR imaging.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.