Abstract

BackgroundThe current study was undertaken to examine total hospital costs per patient of a consecutive implantation series of two 3rd generation Left Ventricle Assist Devices (LVAD). Further we analyzed if increased clinical experience would reduce total hospital costs and the gap between costs and the diagnosis related grouped (DRG)-reimbursement.MethodCost data of 20 LVAD implantations (VentrAssist™) from 2005-2009 (period 1) were analyzed together with costs from nine patients using another LVAD (HeartWare™) from 2009-June 2011 (period 2). For each patient, total costs were calculated for three phases - the pre-LVAD implantation phase, the LVAD implantation phase and the post LVAD implant phase. Patient specific costs were obtained prospectively from patient records and included personnel resources, medication, blood products, blood chemistry and microbiology, imaging and procedure costs including operating room costs. Overhead costs were registered retrospectively and allocated to the specific patient by predefined allocation keys. Finally, patient specific costs and overhead costs were aggregated into total hospital costs for each patient. All costs were calculated in 2011-prices. We used regression analyses to analyze cost variations over time and between the different devices.ResultsThe average total hospital cost per patient for the pre-LVAD, LVAD and post-LVAD for period 1 was $ 585, 513 (range 132, 640- 1 247, 299), and the corresponding DRG- reimbursement (2009) was $ 143, 192 . The mean LOS was 54 days (range 12- 127). For period 2 the total hospital cost per patient was $ 413, 185 (range 314, 540- 622, 664) and the corresponding DRG- reimbursement (2010) was $ 136, 963. The mean LOS was 49 days (range 31- 93).The estimates from the regression analysis showed that the total hospital costs, excluding device costs, per patient were falling as the number of treated patients increased. The estimate from the trend variable was -14, 096 US$ (CI -3, 842 to -24, 349, p < 0.01).ConclusionThere were significant reductions in total hospital costs per patient as the numbers of patients were increasing. This can possibly be explained by a learning effect including better logistics, selection and management of patients.

Highlights

  • The current study was undertaken to examine total hospital costs per patient of a consecutive implantation series of two 3rd generation Left Ventricle Assist Devices (LVAD)

  • The estimates from the regression analysis showed that the total hospital costs, excluding device costs, per patient were falling as the number of treated patients increased

  • Seven patients were on Extracorporeal Membrane Oxygenation (ECMO), while most of the patients were on intra-aortic balloon pump (IABP) prior to the LVAD implantation

Read more

Summary

Introduction

The current study was undertaken to examine total hospital costs per patient of a consecutive implantation series of two 3rd generation Left Ventricle Assist Devices (LVAD). Further we analyzed if increased clinical experience would reduce total hospital costs and the gap between costs and the diagnosis related grouped (DRG)-reimbursement. Prevalence of heart failure has been increasing over the last decade and left ventricular assist device (LVAD). There are currently a variety of LVAD systems available, with different technology [1,2,3,4]. The data consisted of information of patients from two subsequent periods where two different 3rd generation. Costs of the preLVAD work-up and treatment, the LVAD implantation phase as well as the post-LVAD care were evaluated in a setting of implementation of a new treatment program

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us