Abstract

The influence of bed depth on the performance of aerated horizontal constructed wetlands was investigated at the pilot plant scale. Two horizontal flow subsurface constructed wetlands (HF) intensified units of different bed depth (HF1: 0.90 m and HF2: 0.55 m, 0.8 m and 0.5 m water level, respectively) were fitted with forced aeration, while a third one (HFc, 0.55 m bed depth, 0.5 m water level) was used as control and not aerated. The three HF units were operated in parallel, receiving the same municipal wastewater pre-treated in a hydrolytic up-flow sludge blanket anaerobic digester. Applied surface loading rates (SLR) ranged from 20 to 80 g biochemical oxygen demand (BOD5)/m2·d and from 3.7 to 6.7 g total nitrogen (TN)/m2·d, while it ranges from 6 to 23 g BOD5/m2·d and from 1.1 to 1.7 g TN/m2·d in the control unit. Removal of total suspended solids (TSS) and BOD5 was usually close to a 100 % in all units, whilst chemical oxygen demand (COD) removal was higher for the HF1 unit (97 % on average, range of 96–99 %) than for HF2 (92 %, 82–98 %) and HFc (94 %, 86–99 %). TN removal reached on average 33 % (16–43 %) in HFc, 37 % (10–76 %) in HF2 and 51 % (21–79 %) in HF1. High TN removal required a longer aeration time for nitrification and higher effluent recirculation ratio to enhance denitrification. The results indicate that artificial aeration and a high bed depth allows to increase the SLR by a factor of 4 in HF1 but only by a factor of 2 in HF2.