Abstract
The Heidelberg Ion-Beam Therapy Centre’s synchrotron makes use of the sextupole driven RF-KO method near the third-order resonance in order to slowly extract the beam that is delivered to the patients. The horizontal beam response of a coasting beam was studied experimentally and with simulations at extraction conditions in order to deduce regions of interest for an optimal excitation signal spectrum. Two narrow frequency regions were found where the beam reacts coherently. With these information an RF signal was proposed for the resonant slow extraction.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.