Abstract

The use of a transparent hood to improve colonoscopic performance has recently been proposed. The purpose of this study was to evaluate whether using the hood might improve the cecal intubation rate, cecal intubation time, number of attempts needed to intubate the ileo-cecal valve, and polyp detection rate in trainees. Patients undergoing colonoscopy (n = 378) were randomized in two groups, one studied with hood colonoscopy (n = 179) and the other (n = 199) with standard examination. No differences were found between hood and standard colonoscopy with respect to cecal intubation rate (95 vs 92 %), whereas hood colonoscopy significantly shortened the cecal intubation time, the number of attempts needed to intubate the ileo-cecal valve, and the overall polyp detection rate (p < 0.01 for all these variables). Hood colonoscopy might represent a useful adjunct to standard colonoscopy, especially improving the performance of endoscopic trainees.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.