Abstract
Network elements consume 10–20% of the total power in data centers. Today's network elements are not energy-proportional and consume constant energy1 regardless of the traffic amounts. Thus, turning off unused network switches is the most efficient way of saving energy consumption of data center networks. This paper presents Honeyguide, an energy optimizer for data center networks that not only turns off inactive switches but also increases the number of inactive switches for energy-efficiency. To this end, Honeyguide combines two techniques: 1) virtual machine (VM) and traffic consolidation, and 2) a slight extension to existing tree-based topologies. Honeyguide has the following advantages. VM consolidation, which is gracefully combined with traffic consolidation, can handle severe requirements on fault tolerance. It can be introduced into existing data centers without replacing already-deployed tree-based topologies. Our simulation results demonstrate that Honeyguide can save more energy consumption of network elements than conventional VM migration schemes, and the savings are up to 7.8% in a fat tree with k = 12.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.