Abstract

SummaryManagement of COVID-19 and other epidemics requires large-scale diagnostic testing. The gold standard for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection remains reverse transcription quantitative PCR (qRT-PCR) analysis, which detects viral RNA more sensitively than any other method. However, the resource use and supply-chain requirements of RT-PCR have continued to challenge diagnostic laboratories worldwide. Here, we establish and characterize a low-cost method to detect SARS-CoV-2 in clinical combined nose and throat swabs, allowing for automation in high-throughput settings. This method inactivates virus material with sodium dodecylsulfate (SDS) and uses silicon dioxide as the RNA-binding matrix in combination with sodium chloride (NaCl) and isopropanol. With similar sensitivity for SARS-CoV-2 viral targets but a fraction of time and reagent expenditure compared with commercial kits, our method also enables sample pooling without loss of sensitivity. We suggest that this method will facilitate more economical widespread testing, particularly in resource-limited settings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.