Abstract
The effects of modal interference (MI) on the performance of hollow-core photonic bandgap fiber (HC-PBF) gas sensors are investigated. By optimizing mode launch, applying wavelength modulation with proper modulation parameters as well as appropriate digital signal processing, an estimated lower detection limit of <1 ppmv acetylene is achieved with 13-m long HC-PBF. The impacts of drilling side-hole on the MI and response time are also studied. With a 62-cm long sensing HC-PBF drilled with multiple side-holes, an acetylene sensor with a lower detection limit of 11 ppmv and a recovery time of 2 minute is demonstrated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.