Abstract

SummarySmall intestinal biopsies are part of the routine evaluation of children with chronic diarrhea and malabsorption, and are commonly performed via suction capsule. Because this technique entails x‐ray exposure, longer procedure time, and technical failures, most small intestinal biopsies in adults are currently obtained via endoscopy. Endoscopy is believed to yield morphologically inferior specimens, and, therefore, its use for obtaining small intestinal biopsies in children has remained limited. The histological adequacy of biopsy specimens obtained in 30 children by endoscopy and in 30 children by suction capsule was compared. Biopsies were assessed for quality of orientation, size (length and depth), presence of Brunner's glands and crush artifact, and for the ability to confirm or exclude a mucosal abnormality. Small intestinal biopsies obtained via endoscopy were shown to yield tissue specimens that are histologically comparable to those obtained by suction capsule, and that are equally suitable for interpretation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.