New tools are needed to help in evaluating 3-D treatment plans because of the large volume of data. One technique which may prove useful is the application of complication probability calculations. A method of calculating complication probabilities for inhomogeneously irradiated normal tissues is presented in this paper. The method uses clinical estimates of tolerance doses for a few discreet conditions of uniform partial organ irradiation, an empirical fit of a continuous function to these data, and a technique (the effective volume method) for transforming nonuniform dose-volume histograms into equivalent uniform histograms. The behavior of the effective volume histogram reduction method for various boundary conditions is reviewed. The use of complication probabilities in evaluating treatment plans is presented, using examples from an NCI 3-D treatment planning contract.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.