Abstract

This paper gives results concerning the measurement of differential and integral nonlinearity of ADC's using the histogram method with a sine wave input signal. We specify the amount of overdrive required as a function of the noise level and the desired accuracy and the number of samples required as a function of the desired accuracy, the desired confidence level, and the noise level. An analysis of the effect on the results of harmonic distortion of the applied signal is given. The error analysis assumes a mixture of coherent and random sampling rather than pure random sampling.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.