Abstract
BackgroundDislocation continues to be a common complication following total hip arthroplasty (THA). A larger intraoperative range of motion (ROM) is believed to minimize dislocation risk, and intraoperative stability tests have been used to assess the ROM. However, it is not clear whether or not intraoperative stability tests can predict hip stability after THA. It is also unclear which angles are required in intraoperative stability tests. We investigated the usefulness of intraoperative stability tests, and other risk factors to predict hip stability after THA.MethodsPatients operated by single surgeon at one hospital from June 2009 to December 2013 were evaluated. This study included 185 hips with 32 mm metal femoral head. The range of internal rotation with 90° hip flexion (IR angle) was measured as an intraoperative stability test. The variables studied as risk factors included age, height, weight, gender, cerebral dysfunction, preoperative diagnosis, history of previous hip surgery, and IR angle.ResultsMean IR angle was statistically different between patients with dislocation and patients without dislocation (59.5° vs 69.6°: p = 0.006). Cerebral dysfunction and a history of previous hip surgery were statistically related with prevalence of dislocation (p = 0.021, and p = 0.011). The receiver-operating characteristic curve analysis suggested that the cutoff points for IR angle were 51° and 67°. Dislocation rate in larger IR angle group was significantly lower than the rate in smaller IR angle group when patients were divided by 51° (p = 0.002). Logistic regression analyses showed that significant risk factors were cerebral dysfunction (OR: 5.3 (95%CI 1.1–25.9); p = 0.037), history of previous hip surgery (OR: 8.6 (95%CI 1.2–63.0); p = 0.035), and IR angle (OR: 10.4 (95%CI 1.9–57.1); p = 0.007).ConclusionsThe results showed that intraoperative stability test, especially the IR angle, was a useful method to predict hip stability after THA, and a larger intraoperative ROM reduced the likelihood of dislocation. 51° and 67° were indicated as cutoff points for IR angle. Cerebral dysfunction and a history of previous hip surgery are also risk factors for the incidence of dislocation after THA.Trial registrationThis is a retrospective study, not a clinical trial defined by the World Health Organization (WHO).
Highlights
Dislocation continues to be a common complication following total hip arthroplasty (THA)
We investigated the usefulness of intraoperative stability tests, and other risk factors to predict hip stability after THA
This study showed a larger intraoperative range of motion (ROM) reduced the likelihood of dislocation after THA, and 51° was indicated as a cutoff point for IR angle
Summary
Dislocation continues to be a common complication following total hip arthroplasty (THA). A larger intraoperative range of motion (ROM) is believed to minimize dislocation risk, and intraoperative stability tests have been used to assess the ROM It is not clear whether or not intraoperative stability tests can predict hip stability after THA. Many in vitro studies have investigated the ROM of the hip, impingement, and dislocation mechanisms, and they reported the factors related to ROM, including component position, head diameter, and component design [5]. Our hypothesis was that intraoperative stability tests would be effective to indicate hip stability after THA, and that a large intraoperative ROM would reduce the likelihood of dislocation after THA
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.