Abstract
Surgical stabilization followed by early mobilization is the treatment of choice for both nondisplaced and displaced intertrochanteric fractures. Fracture stability is dependent on the status of the posteromedial cortex. The sliding hip screw is the device mostly commonly used for fracture stabilization. The most important aspect of its insertion is secure placement within the femoral head. Although the sliding hip screw allows postoperative fracture impaction, it is essential to obtain an impacted reduction at the time of surgery. If there is a large posteromedial fragment, an attempt should be made to internally fix the fragment with a lag screw or cerclage wire. Although intramedullary hip screws have not been shown to be superior to the sliding hip screw, they may have selected indications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of the American Academy of Orthopaedic Surgeons
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.