Abstract

Pudendal nerve palsy is a reported complication of hip arthroscopy. We report a technique using a deflated taped beanbag rather than a perineal post. The patient is placed in the supine or lateral position on a fracture table. The beanbag is contoured around the patient’s flank and thorax. The distal aspect of the beanbag is placed no further than the iliac crest, and care is taken to avoid compression of the posterior aspect of the axillary region or the posterior humerus. The molded beanbag is deflated, a blanket is positioned over the abdomen and lower thorax, and with the use of 3-in-wide cloth tape, the patient and beanbag are secured to the operative table circumferentially. The superior margin of the deflated beanbag remains firm, preventing compression of the thorax and avoiding compromised ventilation. The arm on the operative side is placed across the chest and secured to avoid obstruction of the operative field. This patient positioning provides sufficient stability for adequate traction and good visualization while minimizing the risk of a pudendal nerve palsy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.