Abstract

High-quality moire-interferometry patterns were obtained with the following conditions: specimen of graphite-polyimide composite material; reflective cross-line specimen grating of 600 l/mm (15,000 l/in.); virtual reference grating of 1200 l/mm (30,000 l/in); fringe-multiplication factor of 2; carrier pattern of 10 fringes/mm (250/in.); carrier eliminated by optical filtering. The phase-type specimen grating was cast onto the composite material with silicone rubber, using a ‘homemade’ mold. The virtual grating was formed with a plane mirror in a collimated field. Precision-quality optical elements are not required.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.