Abstract

The recent achievement of atomic resolution with dynamic atomic force microscopy (dAFM) [Fukuma et al., Appl. Phys. Lett. 2005, 87, 034101], where quality factors of the oscillating probe are inherently low, challenges some accepted beliefs concerning sensitivity and resolution in dAFM imaging modes. Through analysis and experiment we study the performance metrics for high-resolution imaging with dAFM in liquid media with amplitude modulation (AM), frequency modulation (FM) and drive-amplitude modulation (DAM) imaging modes. We find that while the quality factors of dAFM probes may deviate by several orders of magnitude between vacuum and liquid media, their sensitivity to tip–sample forces can be remarkable similar. Furthermore, the reduction in noncontact forces and quality factors in liquids diminishes the role of feedback control in achieving high-resolution images. The theoretical findings are supported by atomic-resolution images of mica in water acquired with AM, FM and DAM under similar operating conditions.

Highlights

  • Since its inception [1], dynamic atomic force microscopy has proven to be a powerful yet versatile tool capable of operating in media ranging from vacuum to liquids and interrogating samples ranging from stiff inorganic materials to soft biological samples, with nanoscale resolution

  • We present high-resolution images of mica in liquids with frequency modulation (FM), drive-amplitude modulation (DAM) and amplitude modulation (AM) acquired with the same probe and under similar operating conditions

  • We have studied the performance metrics for high-resolution imaging in liquids with different dynamic atomic force microscopy (dAFM) imaging modes

Read more

Summary

Introduction

Since its inception [1], dynamic atomic force microscopy (dAFM) has proven to be a powerful yet versatile tool capable of operating in media ranging from vacuum to liquids and interrogating samples ranging from stiff inorganic materials to soft biological samples, with nanoscale resolution. The achievement of atomic-resolution imaging in liquids [2,3,4,5,6] has challenged the accepted belief that high quality factors, which are a hallmark of microcantilever probes in vacuum, are necessary for atomic-resolution imaging [7]. Atomic-resolution images have been obtained with several dAFM imaging modes in liquids despite the quality factors being several orders of magnitude smaller than in vacuum. To improve imaging resolution in liquids, Q-controlled dAFM, which uses feedback control to manipulate the effective quality factor of the oscillating probe, has been proposed [15,16]. The merits of this approach for improving imaging resolution are still under question [17]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.