Abstract
High-resolution x-ray imaging diagnostics play a crucial role in fundamental research, such as inertial confinement fusion (ICF) and high-energy density physics (HEDP). Plasma signals are typically characterized by small scales, rapid evolution, and spectral complexity. These characteristics make it essential to develop x-ray diagnostics optics with high spatial resolution, collection efficiency, and spectral resolution. These requirements can be met using a combination of a high-resolution multi-channel Kirkpatrick–Baez (KB) microscope with spectrum-resolved multilayers and a time-resolved framing camera. This study describes the optical and multilayer design of a dual-energy sixteen-channel KB microscope. The calibrated results of online and offline imaging are shown. By utilizing a dual-energy multi-channel KB microscope, high-resolution backlighting and self-emission x-ray imaging can be realized and detailed information related to plasma density and temperature can be simultaneously obtained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.