Abstract

To assess the usefulness of constructive interference in a steady state (CISS) sequence for an evaluation of cervicothoracic adhesive arachnoiditis. Seven patients with arachnoiditis underwent magnetic resonance imaging with T1- and T2-weighted fast spin-echo (FSE) and 3-dimensional CISS sequences. Three observers compared T2-weighted FSE and 3-dimensional CISS images with regard to image quality for spinal adhesive arachnoiditis. Magnetic resonance appearances accompanied with cervicothoracic adhesive arachnoiditis on CISS coupled with T2-weighted FSE sequences were also evaluated. The CISS images were superior to T2-weighted FSE images in the demarcation of spinal cord, dura matter, nerve root, and adhesive point. In our 7 cases with cervicothoracic adhesive arachnoiditis, dural thickening in 2 cases, syringomyelia in 6, arachnoidal cysts in 3, findings of presyrinx in 2, intramedullary microcyst in 2, and deformity of the spinal cord were present. A CISS sequence was more desirable for an evaluation of the cervicothoracic adhesive arachnoiditis than T2-weighted FSE images and could provide useful additional information.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have