Abstract
The viscosities of olive oil and its constituent fatty acids were measured using a falling sinker-type high-pressure viscometer. The viscometer consists of a titanium cylindrical sinker with ferrite core and descends concentrically under the influence of gravity through a close-fitting titanium tube. The movement of the sinker was detected by electrical induction through coils surrounding the tube. For the oil and fatty acids, the calculated dynamic viscosity increased according to the model η=ηo exp (β p). The coefficients were readily obtained by linearizing experimental data for sinker fall-times and found to be dependent on the chain length and degree of saturation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.