<p>Stable isotope analysis of biogenic carbonates has remained one of the most important tools in paleoceanography since Emiliani (1955) first described the fluctuation of oxygen isotopes in planktic foraminifers over the Pleistocene. Many laboratories now possess equipment with the capability to analyse foraminifer specimens singularly, at least for larger planktic forms.</p><p>Being able to run single specimens of planktic foraminifers is significant, because it yields entirely different information than when one would analyse multiple specimens from the same species. Planktic foraminifers have an average life span of about one month, so analysing single specimens, makes paleoceanographic data at seasonal resolution available (e.g. Ganssen et al., 2011; Metcalfe et al 2019, and references therein).</p><p>Most modern equipment for stable isotope analysis of CaCO<sub>3</sub> samples yields good precision down to 10 microgram sample size. The smallest samples are generally measured with a dual inlet technique, because that quantitatively collects the CO<sub>2 </sub>gas sample in a cold trap before analysis, leading to a more efficient use of the sample gas. Modern dual inlet equipment has a sample size limit somewhere between 10 and 6 microgram CaCO<sub>3</sub> sample weight, and in that range usually operates at increased analytical uncertainty when compared to larger samples (e.g. Ganssen et al., 2011). Smaller samples are problematic, because at small amounts of sample gas, the dual inlet system is not able to maintain viscous flow conditions required for precise isotope analysis. To circumvent that barrier, one can use continuous-flow (CF) mass spectrometry because in CF systems the carrier gas ensures proper flow conditions even if there is (virtually) no sample gas produced. Doing so has previously allowed for the  isotope analysis of CaCO<sub>3 </sub>samples in the 10 – 6 microgram range at an external precision (1SD) of ~0.12‰  for both δ<sup>18</sup>O and δ<sup>13</sup>C (e.g. Metcalfe et al 2019).</p><p>To further improve the performance of CF mass spectrometry for small CaCO<sub>3</sub> samples, we ran experiments on a Thermo GASBENCH system, equipped with a cold trap (cf. Fiebig et al 2005) and interfaced with a Delta-V mass spectrometer. The experiments consisted of replicate analysis of CaCO<sub>3</sub> standards between 10 and 3 micrograms in weight, which is the weight range of many of the smaller specimens of planktic foraminifers.</p><p>Several hardware modifications were implemented to improve system stability and remove observed effects of contribution of blank CO<sub>2</sub> building up in the sample vials. With these modifications, external reproducibility of the set-up for carbonate standard aliquots between 10 and 4 microgram reached a precision of ~0.10 ‰ for both δ<sup>18</sup>O and δ<sup>13</sup>C (1SD). This is similar to precisions typically attained for routine analysis of much larger samples in standard operation on the same equipment, and demonstrates that precise stable isotope analysis of smaller single-specimen planktic foraminifers than we could achieve so far is within reach of CF mass spectrometry.</p><p><strong>

Highlights

  • This page was generated automatically upon download from the ETH Zurich Research Collection

  • The smallest samples are generally measured with a dual inlet technique, because that quantitatively collects the CO2 gas sample in a cold trap before analysis, leading to a more efficient use of the sample gas

  • Modern dual inlet equipment has a sample size limit somewhere between 10 and 6 microgram CaCO3 sample weight, and in that range usually operates at increased analytical uncertainty when compared to larger samples (e.g. Ganssen et al, 2011)

Read more

Summary

Introduction

This page was generated automatically upon download from the ETH Zurich Research Collection. High-precision stable isotope analysis of less than 5 microgram carbonate samples by continuous-flow mass spectrometry Hubert Vonhof1, Stefan de Graaf1, Howard Spero2, Ralf Schiebel1, Suzan Verdegaal-Warmerdam3, Brett Metcalfe , and Gerald Haug

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.