Abstract
A common approach to ablating along the posterior wall of the left atrium in atrial fibrillation ablation is to use low power with longer duration for durable lesions and reducing thermal injury. We hypothesize that similar lesions can be safely obtained at high power with low open-irrigation flow and low duration. Twenty-two porcine ventricles were placed in a tissue bath with circulating 0.45% NaCl at a maintained temperature of 37°C. Bipolar radiofrequency ablation (RFA) with a 4-mm-tip irrigated, force-sensing catheter was performed with various combinations of irrigation, power, and duration at 20g of contact force. Fiber optic temperature probes were placed at depths of 3mm and 5mm. Temperature was measured during and 30s after each ablation. Two hundred sixty-eight lesions were made. At a fixed power and flow rate, lesion surface diameter, maximum lesion width, and lesion depth all increased with longer ablation duration. At fixed duration and irrigation flow rate, increased power led to increased lesion dimensions. At a lower flow rate (2ml/min), surface lesion diameter and maximum width were significantly larger compared to a higher flow rate (17ml/min), but lesion depth was not significantly different. The maximum temperature and the rate of temperature rise at a depth of 5mm with different power settings and ablation durations were lower as compared to a depth of 3mm at both flow rates (2ml/min and 17ml/min). Effective lesions can be performed with high-power and short-ablation durations, thereby reducing RFA procedure time. Higher power, shorter duration lesions result in adequate temperature for myocardial lesion formation at 3mm, but do not result in excessive temperature at 5mm depth, potentially reducing the risk of collateral injury. Compared to higher irrigation flow rate, larger surface lesions and comparable maximum lesion width are achieved with lower irrigation flow rate, thus resulting in better lesion contiguity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Interventional Cardiac Electrophysiology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.