Abstract
High-performance liquid chromatographic (HPLC) analysis of human serum albumin (HSA) on a GS-520 column with 0.03 M sodium phosphate buffer—0.15 M sodium sulphate (pH 6.87) showed three peaks, the principal component corresponding to human mercaptalbumin (HMA) and the secondary and tertiary components to nonmercaptalbumin (HNA). Using HPLC analysis, the nonmercapt → mercapt conversion of HSA during haemodialysis and the mercapt → nonmercapt conversion after haemodialysis in chronic renal failure were re-confirmed, indicating that HMA is a covalent carrier protein for sulphur-containing amino acids. Fractions of HMA in various liver diseases were significantly lower than those of healthy male adults.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.