Abstract

To compare phase contrast microscopy (PCM) of unstained slides for the detection of Cryptosporidium spp. oocysts with a commercially available enzyme immunoassay (EIA) for the detection of cryptosporidial antigen in human stool samples, we prospectively analysed by both methods 463 fresh human stool samples obtained from diarrhoeic patients between July and October 2014. Compared with the EIA, the sensitivity, specificity, positive and negative predictive value of PCM were 88.9 % (95 % confidence interval (CI), 66.0-98.1 %), 100 % (95 % CI, 99.0-100 %), 100 % (95 % CI, 77.3-100 %) and 99.6 % (95 % CI, 98.3-100 %), respectively. Additionally, we retrospectively examined with PCM 65 fixed stool samples that had been collected in 2010 from mostly asymptomatic Rwandan children <5 years of age; 14 of these samples had previously yielded positive results with a highly sensitive real-time (RT)-PCR. PCM detected cryptosporidia in 5/14 RT-PCR-positive samples, and notably, also in one of 51 RT-PCR-negative samples, which was subsequently confirmed by acid-fast staining. Positive and negative percent agreement of PCM with RT-PCR were 35.7 % (95 % CI, 16.2-61.4 %) and 98.0 % (95 % CI, 88.7-100 %), respectively. Positive PCM results were associated with higher RT-PCR cycle threshold values (p = 0.044). In conclusion, PCM offers a highly specific, undemanding and inexpensive method for the laboratory diagnosis of acute human cryptosporidiosis independent of the causative Cryptosporidium species.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call