Abstract

Trace-level Cr2O72– was determined in 2.0 mol dm–3 H2SO4(at 20 °C) with a carbon paste electrode (mixture of liquid paraffin and spectroscopically pure graphite powder, without ionophore) by using a potentiometric method with the linear range within 2.2 × 10–7–3.2 × 10–6 mol dm–3, response slope at 130–180 mV decade–1, and a detection limit at 3 × 10–8 mol dm–3. The respective interferences by 22 common ions were brought under study. An evaluation was made of the recovery of Cr2O72–, with an average value of 99.7%. This method is characterized by simplicity, convenience and speed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.