Abstract

An electrochemical aptasensor for quantitatively detecting glypican-3 (GPC3) was constructed by combining hemin-reduced graphene oxide-platinum (H-rGO-Pt) nanoparticles (NPs) with reduced graphene oxide-gold (rGO-Au) nanoparticles (NPs). Herein, the rGO-Au NPs deposited onto screen-printed electrodes resulted in signal amplification due to their large surface areas. Meanwhile, highly conductive H-rGO-Pt NPs acted as a sensing medium that improved electrical conductivity and as an indicator for monitoring peak current for determination. A GPC3 aptamer (GPC3apt) with a low equilibrium dissociation constant was used as a bio-recognition molecule. GPC3apt specifically captured GPC3 proteins and formed aptamer-GPC3 complexes, which impeded electron transfer and thus hampered the redox signal of hemin in H-rGO-Pt NPs. This developed electrochemical aptasensor showed a linear response to GPC3 (from 0.001 μg/mL to 10 μg/mL) and had a detection limit of 0.001 μg/mL. This work provides a low-cost and highly sensitive detection with and good recovery for GPC3 and holds great promise for the clinical diagnosis of hepatocellular carcinoma.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.