Abstract

A simple and sensitive electrochemical sensor based on poly (l-lysine) modified glassy carbon electrode (PLL/GCE) was developed to sensitively detect methotrexate (MTX) in the presence of sodium dodecyl benzene sulfonate (SDBS). Fourier transform infrared spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry were carried out to characterize PLL film which exhibits excellent electrocatalytic activity toward the oxidation of MTX in 0.1M phosphate buffer solution. In addition, the oxidation peak of MTX remained stable at PLL/GCE in the presence of SDBS and its current increased 8 times compared with that at bare GCE without SDBS. Experimental parameters were optimized with regard to pH, electro-polymerization segment, accumulation time and concentration of SDBS. Under optimum conditions, the square wave voltammograms exhibited that the oxidation peak current was linearly proportional to the concentration of MTX in the range of 5nM – 0.2μM with detection limit of 1.7 (±0.06) nM (S/N=3). Moreover, this method was applied to detect MTX in medicinal tablets with satisfying results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.